- 전체 절연형 플라스틱 케이스 : PCB 샤시 및 딘-레일 버전
- 국제 범용 입력 범위:85 – 264VAC, 47-440Hz
- I/O절연전압4000VAC의 강화 절연
- -40℃~+80℃ 동작 주변 온도 범위
- 과부하/전압 및 출력 단락 보호
- EN 55011/32 Class B 의 EMI노이즈 규격에 충족하는 디자인
- EN 61000-4-2, 3, 4, 5, 6, 8, 11의 EMC내성 규격에 충족하는 디자인
- 제 4판 의료 EMC 표준 EMI EN 55011 & EMS EN 60601-1-2 준수
- 제 3.2판 의료안전규범 준수 IEC/EN 60601-1 & ANSI/AAMI ES 60601-1(2×MOOP) 인증
- 국제 산업 안전 규범 UL 508 준수 (선택항목)
- UL/cUL/IEC/EN 62368-1(60950-1) ITE안전 인증과 CE 마킹
Introducing the MINMAX APM-40 series - an innovative lineup of fully encapsulated AC-DC power modules designed to meet the highest standards in
performance, safety, and reliability. Engineered to excel in challenging environments, these high-performance products boast an extended operating
temperature range of -40℃ to +80℃, ensuring optimal functionality in diverse applications.
With a universal input voltage of 85-264VAC and comprehensive safety approvals, including UL/IEC/EN certifications for medical safety and UL 508 listing,
the APM-40 series is well-equipped for integration into products targeting global markets. These power supply modules have also earned the EMI Emission
EN 55011/32 Class B approval, attesting to their compliance with stringent electromagnetic interference standards.
In alignment with ISO 14971 Medical Device Risk Management, the APM-40 series undergoes a rigorous risk assessment process. This ensures that these
power modules not only meet the demanding criteria for performance but also adhere to safety benchmarks outlined in ISO 14971. In summary, the APM-40
series power modules provide an ideal solution for a wide range of space-critical applications in commercial, medical, and industrial electronic equipment.
Input Voltage Range | 85 - 264VAC (120 - 370VDC) / 47 - 440Hz | ||
Output Voltage Accuracy | ±2.0% typ. | ||
Line Regulation | ±0.5% typ. | ||
Load Regulation | Single | ±1.0% typ. | |
Dual | ±2.0% typ. | ||
Ripple & Noise (20MHz) | 5V | 1.5%Vp-p of Vo typ. | |
others | 1.0%Vp-p of Vo typ. | ||
Efficiency | Up to 85% | ||
I/O Isolation Voltage | 4000VAC min. (Reinforced Insulation) | ||
Operating Ambient Temp. Range | -40°C to +80°C (See Power Derating) | ||
Over Load Protection | >105% min., Hiccup (Auto. Recovery) | ||
Short Circuit Protection | Continuous (Auto. Recovery) | ||
Case Material | Plastic (UL94V-0 rated) | ||
Safety Approval | UL/cUL/IEC/EN 62368-1(60950-1) , UL508, 2xMOPP per 3rd Edition of IEC/EN 60601-1 & ANSI/AAMI ES60601-1, CB-Report, CE Marking |
- 702 타이난시 남구 중화서로 1단 77호
- sales@minmax.com.tw
- (+886)6-2923150#1119
- (+886)6-2923150#1119
- Lise-Meitner-Straße 3, D-64560 Riedstadt-Wolfskehlen
- weborder@emtron.de
- +49(0)6158-8285-0
- +49(0)6158-8285-155
- Robert-Bosch-Str. 25, 63225 Langen, Germany
- markus.mueller@eu.kagafei.com
- +49 (0) 6103 690 390
- +49 (0) 173 700 49 68
- Warwitzstrasse 9 5020 Salzburg
- austria@texim-europe.com
- +43 (0)662 216 026
- +43 (0)662 216 026-66
- Sdr. Jagtvej , 2970 Hørsholm
- nordic@texim-europe.com
- +45 88 20 26 30
- +45 88 20 26 39
- Robert-Bosch-Str. 25, 63225 Langen, Germany
- markus.mueller@eu.kagafei.com
- +49 (0) 6103 690 390
- +49 (0) 173 700 49 68
- Lise-Meitner-Straße 3, D-64560 Riedstadt-Wolfskehlen
- weborder@emtron.de
- +49(0)6158-8285-0
- +49(0)6158-8285-155
- Robert-Bosch-Str. 25, 63225 Langen, Germany
- markus.mueller@eu.kagafei.com
- +49 (0) 6103 690 390
- +49 (0) 173 700 49 68
- Bahnhofstrasse 92, 25451 Quickborn
- germany@texim-europe.com
- +49 (0)4106 627 07-0
- +49 (0)4106 627 07-20
- Martin-Kollar-Strasse 9, 81829 München
- muenchen@texim-europe.com
- +49 (0)89 436 086-0
- +49 (0)89 436 086-19
- Martin-Kollar-Strasse 9 , 81829 München
- italy@texim-europe.com
- +49 (0)89 436 086-0
- +49 (0)89 436 086-19
- Elektrostraat 17 NL-7483 PG Haaksbergen
- nl@texim-europe.com
- +31 (0)53 573 33 33
- +31 (0)53 573 33 30
Comparison | ECAD | Model Number | Output Power | Input Voltage (VAC) | Output Voltage (VDC) | Output Current (mA) | Efficiency | I/O Isolation |
---|